QA Ampero SDM-6RO
Expand your system with 6 new relay outputs. The application ensures full integration of the AMPERO SDM-6RO module via the Modbus protocol. Offers automatic output creation, advanced security settings (Watchdog) and failure behavior definition. Result? Easy and safe technology control without complex programming.



⚡🔌 QA AMPERO SDM-6RO
QA AMPERO SDM-6RO is an advanced application for bidirectional communication (reading and writing) with the AMPERO SDM-6RO expansion module.
This tool addresses the need to increase the number of outputs in an installation and allows their immediate integration into smart home logic.
The application automatically manages the creation of child devices for all 6 relay outputs.
💼 Business Presentation
Ideal solution for larger installations where standard control unit outputs are insufficient.
The application saves time and effort for installation technicians – you don't need to manually create each device separately. Simply connect the module and the application handles device creation in the system.
Additionally, you gain professional safety control thanks to Watchdog functions and default state definitions, which is essential for critical technology management.
📊 Data Analysis and Processing
For clear visualization, work with measurement history, and graphs we recommend integration with SCADA Mervis.
🧪 TRIAL – Trial Version
Verify the functionality of the AMPERO SDM-6RO module integration in your system.
TRIAL version unlocks full functionality for 2 days.
Download here: ⬇️ Download trial version
⚠️ Note
The application communicates directly with the module via ModbusTCP/ModbusRTU converter (not included).
Important: The application does not include bus operation management on a single ModbusRTU bus. With a higher number of devices on the bus or if the interval between readings is set too small, collisions will occur.
We recommend setting read intervals carefully to prevent collisions and ensure stable communication.
⚙️ Key Features
✅ Efficient Management and Safety
- Automatic child device creation: The application generates all 6 outputs in the system automatically.
- Watchdog Safety Function: Active communication monitoring. If the module loses connection with the control unit, it responds automatically.
- Default Value Configuration: Precise definition of what happens after Watchdog activation (e.g., safe shutdown of pumps or valve opening).
- Device Type Selection: Option to choose appropriate type/icon for child devices of digital outputs.
- Read Period Selection: Optimize bus load by setting communication intervals.
✨ Typical Uses
- Expansion of output count for controlling light circuits in an electrical cabinet.
- Technology Control: Switching valves, pumps, contactors, or other loads.
- Critical Applications: Safe control of heating circuits thanks to Watchdog function (protection against overheating during system failure).
- Integration of irrigation systems or blinds.
🔌 Function Requirements
- Installed AMPERO SDM-6RO module.
- ModbusTCP/ModbusRTU converter for communication with the module.
- Properly designed network topology and configured read intervals.
- Free space to upload the application in the control unit.
🧰 Setup and Configuration
- Selection of read period (polling rate) considering collision prevention.
- Configuration of Watchdog time and default output values.
- Selection of visualization for child devices.
🌍 Language Packs
🇨🇿 Czech 🇬🇧 English